SMC Networks SMC6608M Manuel d'utilisateur Page 90

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 113
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 89
Diagnostic Tests
Upon power-up, the TigerSwitch 100 units perform self-
diagnostic tests (See Chapter 3). Diagnostic tests similar to
those performed on power-up can be run using the Configure
button:
1. Use a long press (>2 seconds) to begin function selection.
The Status LED will start to flash to indicate that functions
may be selected. Use short presses (<2 seconds) to cycle
through the status LEDs until the Diagnostic LED lights. Use
a long press to initiate diagnostic tests.
System Diagnostic Tests
The diagnostic test sequence is performed in two stages. The
first stage is the system diagnostic test. The following table
details system level failures, which are indicated in the
Select/Link row of the LED array:
System Failures
A-3
TROUBLESHOOTING
Component Failure LED Array Indicator Column
System ROM 1
System RAM 2
System EEPROM 3
Vue de la page 89
1 2 ... 85 86 87 88 89 90 91 92 93 94 95 ... 112 113

Commentaires sur ces manuels

Pas de commentaire