SMC Networks SMC8624/48T Manuel d'utilisateur Page 317

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 556
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 316
S
YSTEM
M
ANAGEMENT
C
OMMANDS
4-73
Default Setting
Disabled
Command Mode
Global Configuration
Command Usage
The time acquired from time servers is used to record accurate dates
and times for log events. Without SNTP, the switch only records the
time starting from the factory default set at the last bootup
(e.g., 00:00:00, Jan. 1, 2001).
This command enables client time requests to time servers specified
via the sntp servers command. It issues time synchronization requests
based on the interval set via the sntp poll command.
The SNTP time query method is set to client mode when the first sntp
client command is issued. However, if the sntp broadcast client
command is issued, then the no sntp broadcast client command
must be used to return the switch to SNTP client mode.
Example
Related Commands
sntp server (4-71)
sntp poll (4-72)
sntp broadcast client (4-74)
show sntp (4-74)
Console(config)#sntp server 10.1.0.19
Console(config)#sntp poll 60
Console(config)#sntp client
Console(config)#end
Console#show sntp
Current time: Dec 23 02:52:44 2002
Poll interval: 60
Current mode: unicast
Console#