Fig.30.TFTP Server.
NOTE: After the dialog box of the TFTP server program appears,be sure to specify the
working folder within which the downloaded firmware files reside.
NOTE: Make sure the Accept read requests check box of TFTP Server is selected.
NOTE: The LAN IP address of the SMC2582W-B and the IP address of the TFTP
server must be in the same IP subnet for TFTP to work.
NOTE: It is highly recommended that the TFTP server and the to-be-upgraded
SMC2582W-B be connected by Ethernet and on the same LAN.
NOTE: After the firmware is upgraded, be sure to delete the contents of the Web
browser cache,so that the Web management pages can be shown correctly.
NOTE: A failed upgrade may corrupt the firmware and make the SMC2582W-B unstartable.
When this occurs,call for technical support.
TIP: If you want to remotely upgrade the firmware of a deployed SMC2582W-B from the
Internet,adjust the Timeout and Max no.of retries settings of TFTP Server for remote TFTP
upgrade to succeed.
3.3.3.4. Backing up and Restoring Configuration Settings by TFTP
Fig.31.Configuration backup/restore.